Rack-powering Options for High Density

When looking for a data center rack solution, you should be familiar with the alternatives for providing electrical power to high density racks in data centers and network rooms. Learn why your rack power system should adapt to changing requirements, and get guidelines for power rack systems that can reliably deliver power to high-density loads, while adapting to the changing needs of your data centers and networks.

Featured Software Research:

SaaS versus On-premise ERP

Should your business acquire traditional on-premises enterprise resource planning (ERP) solutions? Or should it invest in emerging software-as-a-service (SaaS)–based ERP solutions? Both options have benefits and both have risks. Download this white paper to see how SaaS ERP stacks up against on-premises ERP across eight categories. Read More

Big Data, Mobility, and Green IT: Innovations for Manufacturers and Distributors

Your business is in good company if it is considering big data, mobility, and/or green information technology (IT) solutions. Before making an investment decision, however, it should evaluate its options relative to actual business strategies and operating requirements. Only then will it put itself in a position to make a well-informed investment decision. Download this article to learn more. Read More

You may also be interested in these related documents:

Strategies for Deploying Blade Servers in Existing Data Centers

Blade servers have a major advantage over traditional ones—improving processing ability while using less power per server. But, with their smaller footprint, blades can be much more densely packed, resulting in racks that use up to 20 times the electrical power and generate up to 20 times the heat. This can stress power and cooling system capability. Learn how to create a power and cooling strategy with these guidelines. Read More

Cooling Strategies for Ultra-high Density Racks and Blade Servers

The average power consumed by an enclosure in a data center is about 1.7 kilowatts (kWs), but the maximum power that can be obtained by filling a rack with available high density servers, such as blade servers, is over 20 kW. Find out about the power density values of current and new data centers, and learn practical approaches to creating strategies for deploying high-density computing, with limitations and benefits. Read More

Guidelines for Specification of Data Center Power Density

Conventional methods for specifying data center density don’t provide the guidance to assure predictable power and cooling performance for the latest IT equipment. Discover an improved method that can help assure compatibility with anticipated high-density loads, provide unambiguous instruction for design and installation of power and cooling equipment, prevent oversizing, and maximize electrical efficiency. Read More
 
comments powered by Disqus